Energy Audits

  1. Beaver Garage Energy Audit

    Beaver Garage Energy Audit

    On November 5, 2012, Premier Power Solutions, LLC (PPS) performed an energy audit and conditions assessment of the State College Borough Beaver Avenue Parking Garage. Recommended Energy Conservation Measures (ECMs) included: installation of occupancy sensors, retrofitting existing 400 watt HID fixtures to 120 watt induction lighting, installation of 6 inches of polyurethane foam insulation on restroom and storage room ceilings, installation of induction parking lot lights on the upper deck, and the installation of variable frequency drives.

  2. Fraser Garage Energy Audit

    Fraser Garage Energy Audit

    On November 5, 2012, Premier Power Solutions, LLC (PPS) performed an energy audit and conditions assessment of the State College Borough Fraser Street Parking Garage. Recommended Energy Conservation Measures (ECMs) included: installation of occupancy sensors, retrofitting existing 400 watt HID fixtures with 120 watt induction lighting, replacement of 32 watt fluorescent lamps with 28 watt lamps, installation of induction parking lot lights on the upper deck of the garage and the replacement of outside 175 wall packs to 26 watt LED wall packs.

  3. Bellaire Court Energy Audit

    Bellaire Court Energy Audit

    On November 5, 2012 Premier Power Solutions, LLC (PPS) performed an energy audit and conditions assessment of the State College Bellaire Court. Recommended Energy Conservation Measures (ECMs) included: replacement of 175 watt Outdoor HPS lights with 26 watt LED wall packs, air sealing with silicone acrylic latex caulking and minimal expanding foam, installation of ventilation fans in storage areas, replacement of exit signs with LED models and the replacement of the water heater.

  4. Schlow Library Energy Audit

    Schlow Library Energy Audit

    On November 5, 2012 Premier Power Solutions, LLC (PPS) performed an energy audit and conditions assessment of the Schlow Centre Region Library. Recommended Energy Conservation Measures (ECMs) included: installation of variable frequency drives on pumps, installation of occupancy sensors, replacement of parking garage lights, replacement of 32 watt bulbs with 28 watt bulbs and the use of smart strip plug outlets.

  5. Service Garage Energy Audit

    Service Garage Energy Audit

    On November 5, 2012 Premier Power Solutions, LLC (PPS) performed an energy audit and conditions assessment of the State College Borough Service Garage. Recommended Energy Conservation Measures (ECMs) included: installation of a waste oil furnace, installation of occupancy sensors, replacement of 400 watt HID lighting to High Bay T-5 lighting, replacement of outside wall packs and the use of smart strip plug outlets.

1 of 1 people found this page helpful. Was this page helpful for you? Yes No